Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 1042/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Specifications | ||
Basic functions | Control system | Current Vector General Purpose Inverter. | |
Compatible motor | Induction motors. | ||
Maximum frequency | Vector control: 0~500Hz; V/F control: 0~3200Hz. |
||
Carrier frequency | 0.8kHz~12kHz; Depending on load, can automatically adjust. | ||
Input resolution | Digital: 0.01Hz; Analog: maximum frequency×0.1%. | ||
Control modes | Open vector control (SVC); Closed loop vector control (FVC); V/F (scalar) control. |
||
Starting torque | G type: 0.5Hz/150% (SVC); 0Hz/180% (FVC). P type: 0.5Hz/100%. |
||
Speed range | 1: 100 (SVC) | 1: 1000 (FVC) | |
Speed accuracy | ±0.5% (SVC) | ±0.02% (FVC) | |
Torque accuracy | ±5% (FVC) | ||
Overload capacity | G type: 150% rated current 60s; 180% rated current 3s; P type: 120% rated current 60s; 150% rated current 3s. |
||
Torque boost | Automatic | Manual 0.1%~30.0% | |
V/F curve |
Straight-line V/F curve
Multi-point V/F curve
N-power V/F curve (2-power, 1.4-power, 1.6-power, 1.8-power, 2-power square)
|
||
V/F separation | Two types: complete separation; half separation. AVR output. | ||
Ramp mode | Straight-line ramp S-curve ramp Four groups of acceleration/deceleration time: 0.0-6500.0s |
||
DC braking | DC braking frequency: 0.00 Hz to maximum frequency Braking time: 0.0-36.0s Braking action current value: 0.0%-100.0% |
||
JOG control | JOG frequency range: 0.00-50.00 Hz JOG acceleration/deceleration time: 0.0-6500.0s |
||
Simple PLC | Up to 16 speeds via the simple PLC function or DI terminals | ||
Onboard PID | Process-controlled closed loop control system | ||
Auto voltage regulation (AVR) |
Keep constant output voltage automatically when grid voltage fluctuates. | ||
Overvoltage/Overcurrent stall control |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/overcurrent. | ||
Fast current limit function | Protect inverter from overcurrent malfunctions. | ||
Torque limit and control | It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the FVC mode. | ||
Stop for a second | When the instantaneous outage occurs, the voltage is compensated by the load feedback energy to keep the converter running for a short time. | ||
Personalization features | Fast flow restriction | Avoiding Frequent Overcurrent Faults in Inverters | |
Timing control | Time range: 0.0-6500.0 minutes | ||
Two-motor switchover | Two motors can be switched over via two groups of motor parameters. | ||
Fieldbuses | RS485, Profibus-DP, CANlink, CANopen (extension cards needed) | ||
Powerful background software | Supports frequency converter parameter operation and virtual oscilloscope function. Graphic monitoring of internal state of frequency converter can be realized by virtual oscilloscope | ||
Operations | Command source | Keyboard Control terminals Serial communication port You can perform switchover between these sources in various ways. |
|
Frequency source | 11 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. You can perform switchover between these sources in various ways. | ||
Auxiliary frequency source |
11 auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis. | ||
Input terminal | 6 digital input (DI) terminals (DI5 supports up to 100 kHz high-speed pulse input) 3 analog input (AI) terminals which support 0-10 V voltage input or 0-20 mA current input |
||
Output terminal | 2 digital output (DO) terminals (FM supports 0-10 kHz square wave signal output) 1 relay output terminal 2 analog output (AO) terminals which support 0-20 mA current output or 0-10 V voltage. |
||
Display and panel | LED display | Displays parameters. | |
Key lock | It can lock the keys partially or completely and define the function range of some keys so as to prevent misconducts. | ||
Protection functions | Motor short-circuit detection at power-on, input/output phase loss protection, overcurrent protection, overvoltage protection, under voltage protection, overheat protection and overload protection. | ||
Optional parts | PG card, brake unit, RS485 card, CAN card, Profibus-DP card. | ||
Environment | Location | Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. | |
Altitude | Less than 1000m. | ||
Ambient temperature | -10°C to +40°C (de-rated if the ambient temperature is between 40°C and 50°C) | ||
Humidity | Less than 95%RH, without condensing | ||
Vibration | Less than 5.9m/s2 (0.6g). | ||
Storage temperature | -20ºC~+60ºC. |
Inverter model | Dimensions(mm) | Holes(mm) | Net(Kg) | |||||
W1 | H1 | H | W | D | D1 | |||
H500-0132T4GB | 240 | 760 | 785 | 385 | 305 | 295 | φ8 | 58.7 |